CDW3 3Pole 4Pole 400A to 6300A intelligent Air Circuit Breaker acb

CDW3 air circuit-breakers (ACBs) protect the largest LV lines, carrying currents up to 6300 A. They can be used for source coupling or changeovers. and the rated working voltage is 415V/690V, which is applicable to the limit environmental conditions of AC 50Hz/60Hz, - 40 ℃~70 ℃. To all high-level electrical professionals, CDW3 air circuit-breakers sounds like a saga of innovative breakthroughs. Experience full connectivity of the latest generation, CDW3 air circuit-breakers, with ever-higher energy reliability and efficiency. It is mainly used in distribution network to distribute electric energy, protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. The circuit breaker can be widely used in power stations, factories, mines and modern high-rise buildings, especially in the power distribution system of intelligent buildings.

Products Details

1.Comprehensive upgrade and supplement of the Breaking capacity, Frame type and accessory 2.1600 / 2000 / 2500 / 4000 / 6300A 3.Multiple protection functions of Intelligence controller, not only 4 basic protection + higher protection, and varied of Measuring function, locking protection, remote control Modbus communication and etc. 4.Patent arc extinguishing structure, 3 layers Patented metal filter screen, 13 plates Stainless steel arc extinguishing grid. 5.More than 30 types accessories for choose as below; -Circuit Protection type: Controller, Shunt coil, Closing coil, Under-voltage release, Motor mechanism, Closing contacts, Remote control reset part, N phase circumscribed transformer, Earth current transformer, leakage current transformer, Dual power controller ATS, Signal module, Power module, Under-voltage delay time module. -Mechanical protection: Cable mechanical interlock, connecting-rod type mechanical interlock, Phase barrier, Doorframe etc. -Indicating: Faults indicating contacts, Auxiliary contact, electrical reset. -Connection: External busbar block, Vertical connection block etc.Frame current 
Rated current In(A) 400 1000 ● 1600 ●      ● 2000   2500   3200   4000   6300
630 ● ● ● ● ● ● ●     ● ●  
800 ● ● ● ● ● ● ●     ● ●  
1000 ● ● ● ● ● ● ●     ● ●  
1250   ● ● ● ● ● ●     ● ●  
1600   ● ● ● ● ● ●     ● ●  
2000       ● ● ● ● ● ● ● ●  
2500           ● ● ● ● ● ●  
3200               ● ● ● ●  
4000                   ● ● ●
5000                       ●
6300                       ●