GXB3L-ZG Zigbee energy monitor circuit breaker with RS485

1.Protect the electrical equipment when there is an over-voltage/under-voltage (set the voltage protection) in the line, it also has the overload and short-circuit protection function. 2.High breaking ability, fast tripping, can achieve remote control, product modular guide rail installation. 3.Maintenance can be remote lock, remote unlock, with mechanical locking. 4.Pressure loss protection: when the under-voltage function is opened, with pressure loss protection, that is, the power off trip, at this time, the product cannot be manually closed. 5.voltage, current, leakage current, temperature action value can be set. Real-time voltage, current, leakage current, temperature and power value can be read, with metering function. The manual or automatic mode can be set.

Products Details

1. GXB3L-ZG intelligent circuit breaker is suitable for AC50/60Hz and rated operating voltage 230/400V. For users or loads with rated working current 80A or below. 2. Can protect the electric equipment when there is a overload and short circuit condition. 3. Zigbee intelligent circuit breaker with RS485 metering function. 4. The mobile phone displays the data in real-time,include(voltage,current, power threshold setting, leakage parameters adjustable, electrical parameters, electricity metering, remote control, overload protection, short circuit protection). 5. External WIFI signal reception is strong. 6. Power current monitoring function, can check the year, day, even an hour electricity consumption, keep your electricity consumption clear. 7. Module structure deign can anti-interference,reliable operation and powerful leakage protection system. Special moisture-proof process of the circuit board, effectively protect the safety of the humid environment. 8. Reliably under over-pressure (N-L: 440V) and without any damage.
Model GXB3L-ZG
Name Zigbee Circuit breaker
Rated voltage AC230V(1P 2P)/AC400V(3P 4P)
Rated frequency 50/60Hz
Number of poles 1P 2P 3P 4P(1P without leakage protection)
Over-voltage AC240-300V
Over-voltage recovery value AC220-270V
Setting range of under-voltage value AC140-190A
Under-voltage recovery value AC170-220V
Under voltage operation delay 0.5-6s
Wiring Using the clap wiring terminals
Frame rated current 100A
Rated current(In) 10A 16A 20A 25A 32A 40A 50A 63A 80A 100A
Instantaneous tripping curve B,C,D
Mechanical life 10000times
Electrical life 6000times
Pollution level Level 2
Protection level IP20

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours